Hip

Hip joint loads measured in vivo

Brandl C., Bender A., Schmachtenberg T., Dymke J., Damm P.
Comparing risk assessment methods for work-related musculoskeletal disorders with in vivo joint loads during manual materials handling
Scientific Reports, 2024, https://doi.org/10.1038/s41598-024-56580-7 

Bender A., Schmidt H., Wellner D.L., Duda G.N., Brandl C., Damm P.
In vivo load on knee, hip and spine during manual materials handling with two lifting techniques
Journal of Biomechanics, 2024, https://doi.org/10.1016/j.jbiomech.2024.111963 

Zhou S., Bender A., Kutzner I., Dymke J., Maleitzke T., Perka C., Duda G.N., Winkler T., Damm P.
Loading of the hip and knee during swimming – an in vivo load study
The Journal of Bone and Joint Surgery, 2023, doi: 10.2106/JBJS.23.00218

Alves S.A., Polzehl J. Brisson N.M. , Bender A., Agres A.N., Damm P. and Duda G.N.
Ground reaction forces and external hip joint moments predict in vivo hip contact forces during gait
Journal of Biomechanics, 2022, https://doi.org/10.1016/j.jbiomech.2022.111037 

Haffer H., Bender A., Krump A., Hardt S., Winkler T., Damm P.
Is Training With Gym Machines Safe After Hip Arthroplasty? – An In Vivo Load Investigation
Frontiers in Bioengineering and Biotechnology, 2022, https://doi.org/10.3389/fbioe.2022.857682 

Bender A., Damm P., Hommel H., Duda G.N.
Overstretching Expectations May Endanger the Success of the “Millennium Surgery”
Frontiers in Bioengineering and Biotechnology, 2022, https://doi.org/10.3389/fbioe.2022.789629 

Palmowski Y., Popovic S., Schuster S., Damm P.
In vivo analysis of hip joint loading on Nordic Walking Novices
Orthopaedic Surgery and Research, 2021, https://doi.org/10.1186/s13018-021-02741-7

Damm P., Bender A., Waldheim V., Winkler T., Duda G.N.
Surgical cup placement affects the heating up of total joint replacements
Scientific Reports, 2021, https://doi.org/10.1038/s41598-021-95387-8

Haffer H., Popovic S., Martin F., Hardt S., Winkler T., Damm P.
In vivo loading on the hip joint in patients with total hip replacement performing gymnastic and aerobic excercises
Scientific Reports, 2021: https://doi.org/10.1038/s41598-021-92788-7

Palmowski Y., Popović S., Kosack D., Damm P.
Analysis of hip joint loading during walking with different shoe types using instrumented total hip prostheses
Scientific Reports, 2021: https//doi/10.1038/s41598-021-89611-8
Data Samples

Damm P., Reitmaier S., Hahn S., Waldheim V., Firouzabadi A., Schmidt G.
In vivo hip and lumbar spine implant loads during activities in forward bent postures
Journal of Biomechanics 2019: https://doi.org/10.1016/j.jbiomech.2019.109517

Damm P., Brackertz S., Streitparth F., Perka C., Bergmann G., Duda G.N., Winkler T.
ESB Clinical Biomechanics Award 2018: Muscle atrophy-related increased joint loading after total hip arthroplasty and their postoperative change from 3 to 50 months
Clinical Biomechanics 2019: https://doi.org/10.1016/j.clinbiomech.2019.04.008

Bergmann G., Kutzner I., Bender A., Dymke J., Trepczynski A., Duda G.N., Felsenberg D., Damm P.
Loading of the hip and knee joints during whole body vibration training
PLoS ONE 13(12): e0207014., 2018, https://doi.org/10.1371/journal.pone.0207014
Data Samples Hip and Knee

Bergmann G., Bender A., Dymke J., Duda G.N., Damm P.
Physical Activities That Cause High Friction Moments at the Cup in Hip Implants
The Journal of Bone & Joint Surgery, 2018, doi: 10.2106/JBJS.17.01298
Data Samples

Angelinia L., Damm P., Zander T., Arshad R., Di Puccio F., Schmidt H.
Effect of arm swinging on lumbar spine and hip joint forces
Journal of Biomechanics, 2018, https://doi.org/10.1016/j.jbiomech.2017.09.011

Damm P., Zonneveld J., Brackertz S., Streitparth F., Winkler T.
Gluteal muscle damage leads to higher in vivo hip joint loads 3 months after total hip arthroplasty
PLoS ONE 13(1): e0190626., 2018, https://doi.org/10.1371/journal.pone.0190626

Damm P., Dymke J., Bender A., Duda G., Bergmann G.
In vivo hip joint loads and pedal forces during ergometer cycling
Journal of Biomechanics, 2017, https://doi.org/10.1016/j.jbiomech.2017.06.047
Data Samples

Damm P., Bender A., Duda G., Bergmann G.
In vivo measured joint friction in hip implants during walking after a short rest
PLoS One, published: March 28, 2017

Kutzner I, Richter A, Gordt K, Dymke J, Damm P, Duda GN, Günzl R, Bergmann G.
Does aquatic exercise reduce hip and knee joint loading? In vivo load measurements with instrumented implants
PLoS One, published: March 20, 2017
Data Samples Hip and Knee

Damm P., Kutzner I., Bergmann G., Rohlmann A., Schmidt H.
Comparison of in vivo measured loads in knee, hip and spinal implants during level walking
Journal of Biomechanics, 2016; http://dx.doi.org/10.1016/j.jbiomech.2016.11.060

Bergmann G., Bender A., Dymke J., Duda G., Damm P.
Standardized Loads Acting in hip implants
PLoS ONE 11(5): e0155612., 2016, doi:10.1371/journal.pone.0155612

Damm P, Bender A, Bergmann G
Postoperative Change in In Vivo Measured Friction in Total Hip Joint Prosthesis during Walking.
PLoS ONE 10(3): e0120438., 2016, doi:10.1371/journal.pone.0120438

Damm P, Dymke J, Ackermann R, Bender A, Graichen F, Halder A, Beier A, Bergmann G
Friction in Total Hip Joint Prosthesis Measured In Vivo during Walking.
PLoS ONE 2013;8(11): e78373. doi:10.1371/journal.pone.0078373

Schwachmeyer V, Damm P, Bender A, Dymke J, Graichen F, Bergmann G
In Vivo Hip Joint Loading during Post-Operative Physiotherapeutic Exercises.
PLoS ONE. 2013;8(10): e77807. doi:10.1371/journal.pone.0077807

Damm P, Schwachmeyer V, Dymke J, Bender A, Bergmann G
In vivo hip joint loads during three methods of walking with forearm crutches.
Clin Biomech (Bristol, Avon). 2013 Jun;28(5):530-5

Bergmann G, Graichen F, Rohlmann A, Bender A, Heinlein B, Duda G, Heller MO, Morlock MM
Realistic loads for testing hip implants
Biomed Mater Eng 20(2) 65-75, 2010, Erratum in: Biomed Mater Eng 2010 Jan 1;20(6):381

Bergmann G, Graichen F, Rohlmann A
Hip joint contact forces during stumbling
Langenbeck Arch Surg: 389(1) 53-9, 2004

Stansfield BW, Nicol AC, Paul JP, Kelly IG, Graichen F, Bergmann G
Direct comparison of calculated hip joint contact forces with those measured using instrumented implants An evaluation of a three-dimensional mathematical model of the lower limb
J Biomech: 36(7) 929-36, 2003

Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, Duda GN
Hip contact forces and gait patterns from routine activities
J Biomech: 34(7) 859-71, 2001

Heller MO, Bergmann G, Deuretzbacher G, Claes L, Haas NP, Duda GN
Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients
Clin Biomech: 16(8) 644-9, 2001

Bergmann G, Graichen F, Rohlmann A
Hip joint forces in sheep
J Biomech: 32(8) 769-77, 1999

Bergmann G, Graichen F, Rohlmann A
Loads Acting at the Hip Joint
in: Sedel, Cabanela [Eds] “Hip surgery – new materials and developments”, M Dunitz, London, 1-8, 1998

Bergmann G, Graichen F, Rohlmann A, Linke H
Hip joint forces during load carrying
Clin Orthop Relat R: (335) 190-201, 1997

Bergmann G, Graichen F, Rohlmann A
Is staircase walking a risk for the fixation of hip implants?
J Biomech: 28(5) 535-53, 1995

Bergmann G, Kniggendorf H, Graichen F, Rohlmann A
Influence of shoes and heel strike on the loading of the hip joint
J Biomech: 28(7) 817-27, 1995

Bergmann G, Correa da Silva M, Neff G, Rohlmann A, Graichen F
Evaluation of Ischial Weight Bearing Orthoses, Based on In Vivo Hip Joint Force Measurements
Clin Biomech: 9 225-234, 1994

Bergmann G, Graichen F, Rohlmann A
Hip joint loading during walking and running, measured in two patients
J Biomech: 26(8) 969-90, 1993

Bergmann G, Rohlmann A, Graichen F
[In vivo measurement of hip joint stress 1 Physical therapy]
Z Orthop Grenzgeb: 127(6) 672-9, 1989

Bergmann G, Siraky J, Rohlmann A, Koelbel R
A Comparison of Hip Joint Force in Sheep, Dog and Man
J Biomech: 17 907-921, 1985

Hip joint temperatures measured in vivo

Bergmann G, Graichen F, Dymke J, Rohlmann A, Duda GN, Damm P
High-tech hip implant for wireless temperature measurements in vivo
PLoS ONE 7(8): e43489. doi:10.1371/journal.pone.0043489

Bergmann G, Graichen F, Rohlmann A, Verdonschot N, van Lenthe GH
Frictional heating of total hip implants Part 2: finite element study
J Biomech: 34(4) 429-35, 2001

Bergmann G, Graichen F, Rohlmann A, Verdonschot N, van Lenthe GH
Frictional heating of total hip implants Part 1: measurements in patients
J Biomech: 34(4) 421-8, 2001

Selected Abstracts

Damm P., Bender A., Bergmann G.,
In vivo Reibung im künstlichen Hüftgelenk beim Gehen sowie deren Änderung im postoperativen Verlauf
Endoprothetik Kongress Berlin; 2016; Berlin; Germany

Damm P., Bender A., Duda G., Bergmann G.
In vivo Belastungen und Kontaktpunktverlauf an der künstlichen Hüftgelenkpfanne bei alltäglichen Aktivitäten
Endoprothetik Kongress Berlin; 2016; Berlin; Germany

Kutzner I., Gordt K. , Richter A., Dymke J., Damm P., Duda G., Günzl R., Bergmann G.
Die Entlastung des Hüft- und Kniegelenks im Wasser – in vivo Messungen mit instrumentierten Implantaten bei der Wassergymnastik
Endoprothetik Kongress Berlin; 2016; Berlin; Germany

Trepczynski A., Damm P., Bergmann G., von Roth P., Duda G.
Bedeutung oberflächlicher Hüftbeuger für die Gelenkbelastung beim Gehen
9. Endoprothetik Kongress; 2016, Berlin, Germany

Kutzner I., Richter A., Gordt K., Dymke J., Damm P., Bergmann G.
Hip and knee joint loading during aquatic exercise – The load reducing effect of water
European Congress of Physical and Rehabilitation Medicine, 2016, Lisbon, Portugal

Damm P.
Wie kann der Patient die Belastung auf das Hüftgelenk minimieren?
18. AE Kongress „Risikominimierung und Komplikationsmanagement“, 2016, Berlin, Germany

Damm P., Kutzner I. Duda G., Bergmann G.
Die Belastung des Hüft- und Kniegelenkes – In vivo Messungen mit instrumentierten Implantaten
Deutscher Verband für Materialforschung und –prüfung e.V., Arbeitskreis „Zuverlässigkeit von Implantaten und Biostrukturen“; 2015; Berlin; Germany

Damm P.
Biomechanische Belastungen im Hüftgelenk
Arbeitsgemeinschaft Endoprothetik; AE-Kurs Hüfte; 2015; Berlin; Germany

Damm P., Laub M., Bender A., Bergmann G.
In vivo Belastung der künstlichen Hüftgelenkpfanne beim Gegen,
Jahrestagung der Deutschen Gesellschaft für Biomechanik; 2015; Bonn; Germany

Damm P., Bender A., Bergmann G.
Postoperative Änderung der Reibung im künstlichen Hüftgelenk beim Fahrradfahren,
Jahrestagung der Deutschen Gesellschaft für Biomechanik; 2015; Bonn; Germany

Damm P., Schmuck D., Dymke J., Bergmann G.
Untersuchung des Einflusses unterschiedlichen Schuhwerks auf die in vivo Hüftgelenkbelastung beim Gehen,
Jahrestagung der Deutschen Gesellschaft für Biomechanik; 2015; Bonn; Germany

Damm P., Schwachmeyer V., Dymke J., Bergmann G.
In vivo bei physiotherapeutischen und sportlichen Aktivitäten
19. Bad Kösener Symposium; Bad Kösen; 2015; Germany

Damm P., Bender A., Bergmann G.
In vivo loads at the artifical acetabulum during walking
Congress of the European Society of Biomechanics; 2015; Prague; Czech Republic

Damm P., Bender A., Bergmann G.
Postoperatively change of the in vivo measured friction in total hip joint replacement during walking
Congress of the European Society of Biomechanics; 2015; Prague; Czech Republic

Damm P., Bender A., Bergmann G.
In vivo Belastung der künstlichen Hüftgelenkpfanne beim Gehen
Deutscher Kongress für Orthopädie und Unfallchirurgie; 2015, Berlin; Germany

Damm P., Schwachmeyer V., Krump A., Dymke J., Bergmann G.,
In vivo Hüftgelenkbelastungen beim Training an Fitnessgeräten,
Endoprothetik Kongress Berlin; 2014; Berlin; Germany

Damm P., Bender A., Bergmann G.,
Postoperative Änderung der in vivo Reibung im künstlichen Hüftgelenk beim Fahrradfahren;
Endoprothetik Kongress Berlin; 2014; Berlin; Germany

Schuster S., Bergmann G., Dymke J., Damm P.,
Die in vivo Hüftgelenkbelastung beim Nordic Walking;
Endoprothetik Kongress Berlin; 2014; Berlin; Germany

Schmuck D., Bergmann G., Dymke J., Damm P.,
Untersuchung des Einflusses unterschiedlichen Schuhwerks auf die in vivo Hüftgelenksbelastung beim Gehen;
Endoprothetik Kongress Berlin; 2014; Berlin; Germany

Damm P., Bender A., Bergmann G.
Post operatively change of the in vivo measured friction during walking in 9 patients with total hip joint replacement;
7th World Congress of Biomechanics; 2014; Boston; USA

Damm P., Bender A., Bergmann G.;
Die in vivo wirkende Reibung im künstlichen Hüftgelenk;
8. Jahrestagung der Deutschen Gesellschaft für Biomechanik; 2013; Neu-Ulm; Germany

Kutzner I., Damm P., Schulze H. , Bergmann G.,
Die Belastung des Knie- und Hüftgelenks beim Vibrationstraining;
8. Jahrestagung der Deutschen Gesellschaft für Biomechanik; 2013; Neu-Ulm; Germany

Damm P., Bender A., Graichen F., Bergmann G.;
In vivo measurements of friction in total hip joint prostheses during walking 3 and 12 months post-operatively;
XXIV Congress of the international society of biomechanics; 2013; Natal; Brasil

Bergmann G., Bender A., Graichen F., Damm P.;
Is insufficient joint lubrication a co-factor for development and progression of arthrosis?;
19th Congress of the European Society of Biomechanics; 2013; Patras; Greece

Damm P.; Bender A., Bergmann G.,
Influence of the resting period on the in vivo friction in hip joint replacement;
19th Congress of the European Society of Biomechanics; 2013; Patras; Greece

Damm P., Kutzner I., Schulze H., Bergmann G.,
Die Belastung der Hüft- und Kniegelenke beim Vibrationstraining mit einem Galileo-2000-System;
Deutscher Kongress für Orthopädie und Unfallchirurgie; 2013; Berlin; Germany

Damm P., Bergmann G.,
In vivo Belastungsmessungen am künstlichen Hüftgelenk;
Kolloquium Biomedizinische Technik, Helmholtz-Institut für Biomedizinische Technik der RWTH Aachen; 2013; Aachen; Germany

Damm P., Ackermann R., Bender A., Graichen F., Bergmann G., 2013
Die in vivo wirkende Reibung am künstlichen Hüftgelenk
Endoprothetik Kongress, Berlin

Damm P., Bender A., Graichen F., Bergmann G., 2013
In vivo friction in total hip replacement during walking
ORS Congress, San Antonio/USA

Damm P., Ackermann R., Bender A., Graichen F., Bergmann G., 2012
In vivo measurements of the friction moment in total hip joint prostheses during walking
ESB Congress, Lissabon/Portugal

Damm P., Dymke J., Schwachmeyer V., Bender A., Halder A.M., Beier A., Bergmann G., 2012
In vivo Hüftgelenkbelastung beim Sport
DKOU, Berlin

Damm P., Dymke J., Bender A., Halder A., Beier A., Graichen F., Bergmann G., 2012
Belastung des künstlichen Hüftgelenkes bei sportlichen Aktivitäten
Endoprothetik Kongress, Berlin

Damm P., Dymke J., Bender A., Halder A., Beier A., Graichen F., Bergmann G., 2012
Hip Joint Loading during Walking with Crutches
EFORT, Berlin

Damm P., Bender A., Dymke J., Graichen F., Bergmann G., 2011
Postoperative Änderung der in vivo Hüftgelenksbelastung beim Gehen mit Gehstützen
DGfB, Murnau

Damm P., Bender A., Dymke J., Halder A.M., Beier A., Bergmann G., 2011
Belastung von Hüftendoprothesen beim Gehen mit Gehstützen
DKOU, Berlin

Damm P., Graichen F., Rohlmann A., Bender A., Bergmann G., 2010
An instrumented total hip joint prosthesis for in vivo measurement of forces and moments
ESB, Edinburgh/England

Damm P,  Graichen F, Bender A, Bergmann G, 2009
Entwicklung einer instrumentierten Hüftendoprothese zur Messung der in vivo auftretenden Kräfte und Momente
Deutscher Kongress für Biomechanik, Münster, 114

Bergmann G, Graichen F, Rohlmann A, 2004
Regular loading meets extremes
ESB Congress, ’s-Hertogenbosch/The Netherlands, CD-ROM

Taylor WR, Heller MO, Bergmann G, Duda GN, 2004
Tibio-femoral loading during human gait and stair-climbing
ESB Congress, ’s-Hertogenbosch/The Netherlands, CD-ROM

Morlock M, Bergmann G, Honl M, 2004
Hip joint loading modes and loading frequencies of total hip arthroplasty patients – implications for pre-clinical testing
ESB Congress, ’s-Hertogenbosch/The Netherlands, CD-ROM

Bergmann G, Graichen F, Rohlmann A, 2002a
Hip contact forces – some important observations
IV World Congress of Biomechanics, Calgary/Canada CD-Rom

Bergmann G, Graichen F, Rohlmann A, 2002b
Investigation of potential separation between head and cup of total hip implants
Proc 48th Ann Meeting Orthop Res Society, Dallas/USA, 0982

Bergmann G, Graichen F, Rohlmann A, Morlock MM, Heller M, Duda GN, 2002d
Realistic Test Scenarios for Hip Implants
Int Conf ‘Engineers & Surgeons – Joined at the Hip’ Inst Mechanical Engineers, London

Stansfield BW, Nicol AC, Paul JP, Kelly IG, Graichen F, Bergmann G, 2002
Hip joint forces, calculated and measured: An evaluation of musculo-skeletal modelling
Int Conf “Engineers & Surgeons – Joined at the Hip”, I Mech E, London/England, abstract C601/007/2002

Heller M, Bergmann G, Deuretzbacher G, Claes L, Duda GN, 2000a
Proximal femoral loading increases with anterversion: measurements and simulation in 4 patients
Proc of 10th Conf EORS, Wiesbaden, O-13

Heller M, Bergmann G, Deuretzbacher G, Claes L, Haas NP, Duda GN, 2000b
Influence of femoral anteversion on proximal femoral loading: measurement and simulation in 4 patients
12th Conf Europ Soc Biomech, Dublin, Betaprint, Dublin, 13

Heller MB, Deuretzbacher G, Duda G N, 2000
Hip Contact and Proximal Femoral Loading Increases with Anteversion: Measurements and Simulations in 4 Patients
25 Ann Meeting Orthopaedic Research Society, Orlando, 0297

Lenthe GHv, Verdonschot N, Bergmann G, Huiskes R, 2000a
The effect of implant material on friction induced heating around total hip implants
Proc of 10th Conf EORS, Wiesbaden, O-38

Lenthe GHv, Verdonschot N, Bergmann G, Huiskes R, 2000b
The effect of implant material on friction induced heating around total hip implants
12th Conf Europ Soc Biomech, Dublin, Betaprint, Dublin 143

Bergmann G, Graichen F, Rohlmann A, 2000a
Do head and cup of total hip implants separate during walking?
Proc of 10th Ann Conf EORS, Wiesbaden, O-40

Bergmann G, Graichen F, Rohlmann A, Verdonschoot N, van Lenthe GH, 2000b
Frictional heating in and around total hip implants
12th Conf Europ Soc Biomech, Dublin/Irland, Betaprint, 142

Bergmann G, Graichen F, Rohlmann A, 1999
Reibungsbedingte Erwärmung von Hüftendoprothesen
Abstraktband 1 Tagung Deutsche Gesellschaft für Biomechanik, Ulm, 21

Graichen F, Bergmann G, Rohlmann A, 1999
Implantable telemetry system for measurement of hip joint force and temperature
15th Int Symposium on Biotelemetry, Juneau/ALASKA (USA) 64

Morlock MM, Bluhm A, Vollmer M, Müller V, Honl M, Hille E, Schneider E, Bergmann G, 1999
Quantification of duration and frequency of every day activities in total hip patients with a mini computer based system
Proc XVIIth ISB Congress, Calgary, 84

Bergmann G, Graichen F, Rohlmann A, 1996a
The loosening forces in hip replacement
20th World Congr SICOT, Amsterdam, 116

Bergmann G, Graichen F, Rohlmann A, 1996b
Measured and calculated hip joint forces during load carrying
10th Conf Europ Soc Biomech, Leuven, 266

Bergmann G, Graichen F, Rohlmann A, 1994
Hip Joint Loading During Load Carrying
2nd World Congr of Biomechanics, Amsterdam, 337

Bergmann G, Graichen F, Rohlmann A, and Wolff, R, 1993
Loading of Hip Joint Implants During Cycling
39th Ann M Orthop Res Soc, 526

Bergmann G, Correa da Silva M, Rohlmann A, Neff G, Graichen F, 1992a
Load reduction achieved by ischial weight bearing orthoses
Proc 2nd Conf Europ Orthop Res Society, Varese, 27

Bergmann G, Graichen F, Rohlmann A, 1992c
Load Reduction of Hip Joint Implants by Forearm Crutches
Proc 8th Meet Europ Soc Biomech, Rome/Italy, 300

Bergmann G, Graichen F, Rohlmann A, 1992d
Loading of Hip Implants by Torsional Moments
38th Ann Meet Orthop Res Soc, Washington, 19

Bergmann G, Graichen F, Rohlmann A, 1991a
In vivo measurement of temperature rise in a hip implant
Proc 37th Ann Meet ORS, Anaheim/Californien 223

Bergmann G, Graichen F, Rohlmann A, 1991c
Messung der Hüftgelenkbelastung bei zwei Patienten
Proc 25 Jahrestag Dtsch Ges Biomed Technik, Berlin, 204-205

Bergmann G, Graichen F, Rohlmann A, 1990c
Postoperative bed rest for patients with cementless hip implants?
Proc 18th Int World Congr SICOT, Montreal/Canada, 245

Bergmann G, Graichen F, Rohlmann A, 1989b
Five month in vivo measurement of hip joint forces
Proc 12th Congr Int Soc Biomech, Los Angeles/USA, J Biomech 22 986 Forschungsvermittlung der Freien Universität, Berlin, 35-63 pp