Hip joint force and motion capture data

Data samples of whole 3D body kinematik and synchroneously in vivo measured hip joint loads are now available at the database, for ‘Level Walking’ and ‘One Legged Stance’. The data samples (table) were used in the new publication “Patient-specific musculoskeletal modeling of the hip joint for preoperative planning of total hip arthroplasty: A validation study based on in vivo measurements“.

The data sets contain the following information:

  • in vivo measured hip joint loads
  • whole body kinematics (marker trajectories)
  • ground reaction forces

To select the data go to: Database

  1. Implant: “Hip Joint III
  2. Activity: “Gaitanalysis; Standing; One Legged Stance; Ipsilateralor “Gaitanalysis; Walking; Level Walking
  3. See “Additional Data” for the motion capture files (*_mov)

Alternatively use the “file search” window at the Database (top left side) by using the given file names (table).

Table: File names of availible data sets

Subject One-leg stance Level walking
H1L H1L_060511_1_24 H1L_060511_1_47
H2R H2R_150811_1_24 H2R_150811_2_98
H3L H3L_141111_2_75 H3L_141111_1_28
H4L H4L_270112_1_36 H4L_270112_2_80
H5L H5L_050412_1_37 H5L_050412_1_75
H6R H6R_201112_1_36 H6R_201112_2_107
H7R H7R_191112_1_38 H7R_191112_1_47
H8L H8L_240413_1_36 H8L_240413_1_48
H9L H9L_301013_1_29 H9L_301013_1_62
H10R H10R_300114_1_32 H10R_300114_1_82

 

 

comments



Database has become fast now

The Orthoload database has now become much faster. In addition, the data selection options have become more flexible. For example, it is not only possible to select Hip Joint III data for

Activity: Walking; with Crutches; 4 Points

but also for

Activity: Walking; with Crutches (with all data for ‘4 Points’, ‘3 Points; Swing Through’ and ‘on Contralateral Side;’)

or

Activity: Walking (with all kinds of walking data for Hip Joint III in the database).

Visit our database page to test the new possibilities!

 

 

comments

CAMS-Knee project online

Knowledge of the internal joint loading and movement following total knee replacement is necessary in order to understand implant stability, wear mechanisms, and loading of the surrounding soft tissue structures. In order to achieve a deeper understanding of knee joint biomechanics, the CAMS-Knee project provides synchronous data of the following measures:

TKR loading (instrumented implants, three forces and three moments)
TKR kinematics (moving fluoroscope, 3D reconstruction of tibio-femoral implant kinematics)
Whole body kinematics (marker-based movement analysis)
Ground reaction forces (force plate data)
EMG (lower limb, 16 channel)
Video (patient movement)
Multiple subjects, multiple activities, multiple repetitions

comments

HIP98

After 16 years of very frequent use of this animated data collection of hip joint forces, an error was detected in the vector diagrams of the contact forces. The x- and y-components had been interchanged. This has now been corrected. We thank Ruchi Chande for her hint to this error!

comments



Comprehensive data samples

Comprehensive data samples, including synchronous joint kinetics and whole body kinematics are now available for free download. The loads acting in human joints were measured at the Charité in Berlin directly in patients by using instrumented implants. Additionally to the joint contact forces kinematic and kinetic data were synchronously captured in patients with instrumented knee and hip implants at the motion analysis lab of the Julius Wolff Institute and the Humboldt University of Berlin. For the analysis of various biomechanical issues comprehensive data sets were prepared.

The comprehensive data sets contain the following information:

  • joint contact forces and moments
  • whole body kinematics (marker trajectories)
  • ground reaction forces

Sample data sets are now released for free download which consist of 1 walking trial from one total knee and one total hip replacement subject.

comments